Richard  .

Richard . Job Checkin

Today I arrived on site to address the thermostat issue. Actions Taken: Addressed a thermostat not displaying anything. Identified the affected zone as the Heating system 1st Floor. Confirmed the living room thermostat was not working. Replaced the thermostat during this visit. Verified the system is now operating. When arriving at the client's property. The client's wife explained to me that for some reason the tstat of the living room area is not working. The client mentioned that her husband tried with new batteries but the tstat did not respond. I proceeded to verify the tstat. The tstat is dead, I explained to the client about the situation. I recommended to the client that it was necessary to replace the tstat. I presented you with an estimate on the cost of installing a new tstat. The client accepted that the tstat be replaced. I proceeded to disassemble the existing tstat. I proceeded to disconnect the wires from the existing tstat. I proceeded to install the new Hon


Lorenzo M.

Lorenzo M. Job Checkin

Upon arrival had thermostat call for heat. Proceed to check status of boiler. Boiler is not displaying any error code. Boiler keeps cycling and won’t ignite to fire. Tried to reset boiler. Remove and clean flame sensor /flame rod. Boiler still won’t ignite. Control module is clicking on/off. Module is not displaying that boiler is providing flame. Reach out to Burnham rep that had me run a number of test on boiler. We tried to bypass all sensors and high limit switch boiler still won’t ignite to fire. Follow up is needed with Burnham rep on site to check boiler operation. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-C175048FC7F742F685E04FFE685A11E0


Nigel  B.

Nigel B. Job Checkin

To replace the defective domestic hot water expansion tank and install a condensate pump with neutralizer reservoir Completed installation of condensate neutralizer pump with neutralizer rocks also completed installation of expansion tank for domestic hot water indirect tank tested all systems. Left systems working. View visual findings from this job here - https://visionshare.xoi.io/?id=XA-90AE-F22265E58E8B4DC89E8F64254B9BF54B check number 101


Richard  .

Richard . Job Checkin

Gas Steam Boiler Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, vacuumed-ok Check and cleaned flame sensor & Pilot Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Flue Pipe-ok Check GVD- Flue Damper-ok Check LWCO-okay Check and cleaned pressuretrol pigtail-ok Check and make leak test-ok, it is not leak at this moment Check relief valve-ok Check and clean pressure retrol-ok Check Automatic water feeder-ok Check Temperatures & settings-ok Flush boiler twice. Check and run Thermostat- operating Check and checked HWH. Check for leak, no leakage at this moment. Check gas control valve-ok Check safeties-ok Check air combustion and draft-ok HWH operating fine at this moment. Run and test system, runs fine, left system operating well at this time. -/-/-/-/-/- Notes: Walkthrough the client for AC &


Lorenzo M.

Lorenzo M. Job Checkin

Maintenance was completed by Mark on 10/03/2025


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-4F35659E7F2142D8A6C57C39602ACFB9 Return to replace steam valve on bathroom radiator and install steam vent on bedroom radiator on second floor: * at arrival boiler is OFF * removed the existing steam vent that is broken in the second floor bathroom * prep the new steam vent with Teflon and pipe dope * install and secure the new steam vent into bathroom radiator * removed the plug in the bedroom radiator where the steam vent is installed * prep the new steam vent with Teflon and dope- install and secured new steam vent into bedroom radiator * with customer turn on steam boiler and call for heat- boiler fires * Monitor flames and system operations/ sight glass level- okay * Confirm that the radiators are all heating properly and new steam vents are installed and operational * In one of the customers second floor bedrooms- a steam radiator was removed and a baseboard section was installed. This does not he


Nigel  B.

Nigel B. Job Checkin

Performed maintenance on one steam boiler with a hydronic loop for the Lennox air handler/hydro coil and one carrier heat pump checked electrical and mechanical components and electrical connections also checked and change filters and performed a carbon monoxide test none detected checked system operation left systems working but turned off at the thermostat View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-49B13DAA9B30441EBF07446132C34DEE


Lorenzo M.

Lorenzo M. Job Checkin

1 Gas Hot Water Boiler: Well McLean Steam Boiler- Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger Check and clean Burners tubes and heat exchanger- ok, vacuumed-ok Check pilot assembly. Thermocouple replaced last year, customer did not want to move forward with thermocouple replacement @ time of maintenance. Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Exhaust-ok Check Temperatures & Water pressure settings; Performance-ok Check and run Thermostats- operating well at this time. Check automatic water feeder, automatic low water cut off, and vent damper. Check for water leak no leakage at this moment. Run and monitored for good operation. Supply and return lines getting hot. Perform check for 50gal HWH. Check for water leak, no leakage at this time. Check control gas valve-ok Check air Combustion and Draft-ok Run and monitored for good


Nigel  B.

Nigel B. Job Checkin

Performed maintenance on one Fujitsu multi zone condenser and three indoor fan coils also performed maintenance on one dunkirk steam boiler removed and cleaned the burners and igniter and flame sensor and cleaned the pressuretroll also cleaned out the burner tray turned system on and checked operations left systems working homeowner is interested in replacing the Fujitsu system one outdoor condenser and three indoor fan coils please see photos of the equipment


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-4656D6425ECB4CA0A2C8607EDC93FEB5 The customer would like the valve reviewed that was installed over the summer- Gary stated that he did not test the valve and that the boiler would need to run to fill the reservoir tank: * At arrival, the customer brought me to the reservoir tank, which had water standing on the floor next to it * The customer stated that this water appeared this morning and was not there yesterday * After reviewing and checking for leaks in all areas- Found that the only source of water was the reservoir tank * There are water marks and rusting stains all over the reservoir tank * At this time, the boiler was found with the switch off and the boiler completely empty from Gary’s repair * There is no automatic water fee on this boiler- You need to manually feed boiler into the system. * Manually fill the boiler to the correct level in the sight glass * Return power to the boiler * Conf


Richard  .

Richard . Job Checkin

Gas Steam Boiler Perform a tune-up and cleaning to help ensure reliable and safe operation. Inspect for cracks & deterioration of Heat Exchanger. Check and clean Burners, vacuumed-ok Check and cleaned flame sensor & Pilot Assembly-ok Check Safety Controls-ok Check electrical wiring and components-ok Check Gas valve & Gas Line-ok Check Combustion Air & Flue Pipe-ok Check GVD- Flue Damper-ok Check LWCO-okay Check and cleaned pressuretrol pigtail-ok Check and make leak test-ok, it is not leak at this moment Check relief valve-ok Check and clean pressure retrol-ok Check Automatic water feeder-N/A Check Temperatures & settings-ok Flush boiler twice. Check and run Thermostat- operating Check and checked HWH. Check for leak, no leakage at this moment. Check gas control valve-ok Check safeties-ok Check air combustion and draft-ok HWH operating fine at this moment. Run and test system, runs fine, left system operating well at this time.. -/-/-/-/-/-/-/-/- - Richard Dominguez visited Mrs. - Mrs.


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-94B8088BC41F490DA8973243DEA9CE8B Perform maintenance on Burnham steam boiler: Show power to the boiler removed flame Guard and rollout switch Removed all burner tubes from boiler Remove thermocouple and pilot assembly from boiler Vacuum and dusted out Burner section of boiler Vacuum and dusted all piping and component Vacuumed and brushed all burner tubes, clean and clear Customer approved replacement of thermocouple Cleaned pilot gas orifice, which was completely plugged Removed existing thermocouple and installed brand new securing connections in gas valve and pilot assembly Reinstalled oil, burner tubes, flame, guard, and rollout switch Inspected heat, exchanger, flue, piping, and damper motor Drain dirty water from boiler and flush simultaneously with freshwater Fill boiler back up to correct level in cycle glass and return power to system Customer called for a heating from his Mitsubishi app, which


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-213F-685C8F04606D4A18AC58EFBD0BE28EBC Return to replace igniter on Navien gas water boiler that serves (2) hydro heating zones and indirect storage tank for DHW: shut power to boiler removed boiler cover door disconnected electrical wiring from igniter and flame rod assembly removed existing igniter and flame rod from boiler as well as gasket installed brand new igniter and flame rod with new gaskets inside boiler and secure in place install and secure electrical wiring and ground to igniter assembly review all connections before returning power to boiler once power is restored- indirect tank is calling for heat and boiler fires- circulator pump is on and running- normal operations smooth ignition- okay monitor operations until indirect tank is satisfied and system is back on stand by repair is made, system is tested and operational


Nigel  B.

Nigel B. Job Checkin

Completed maintenance on one lochinvar Knight boiler removed and inspected and cleaned the igniter and flame sensor and inspected the burner also cleaned condensate reservoir and flushed it checked expansion tanks the domestic hot water expansion tank is defective and will need to be replaced also recommend to replace the neutralizer canister and condensate pump to a upgraded combo pump and neutralizer reservoir checked system operations left system working


Mark E.

Mark E. Job Checkin

View visual findings from this job here - https://visionshare.xoi.io/?id=XA-AB08-B464EB80B5C343AC850B56A9CAD525A1 Perform maintenance on one Navion gas fired water boiler with two Hydro air, handlers and domestic hot water indirect tank: GAS WATER BOILER: low water cut off was just replaced and tested on system Remove the bottom of condensate trap Removing all dirty water from system, Cleaned cap and reinstalled securing in place Flushed and tested neutralizer kit and condensate pump- All water is flowing into pump- No leaks normal operations Neutralizer minerals in good condition with minimal wear Removed fresh air intake screen, Cleaned and reinstalled Removed flame rod and spark igniter- Showing extremely heavy wear and igniters are morphed- Replacement is highly recommended Vacuumed and dusted out inside of boiler cabinet and components Secured electrical wiring and connections Inspected inside of boiler cabinet for leaks or corrosion Test and check expansion tank, Water feed